Fan Ps-1 Is Faulty

Fan Ps-1 Is Faulty



i have two WS-C3750X-24T-S connected in stack , when i typed show env all i got FAN PS-2 is FAULTY as following FAN 1 is OK FAN 2 is OK FAN PS- 1 is OK FAN PS-2 is FAULTY SYSTEM TEMPERATURE is OK System Temperature Value: 26 Degree Celsius System Temperature State: GREEN Yellow Threshold : 46 Deg…

11/30/2020  · Symptom: PS- FAN falls to FAUTY status after upgrading your IOS software. The show env stack command displays the following SWITCH: 1 FAN 1 is OK FAN 2 is OK PS-FAN1 is FAULTY PS-FAN2 is NOT PRESENT TEMPERATURE is OK Temperature Value: 35 Degree Celsius Temperature State: GREEN Yellow Threshold : 46 Degree Celsius Red Threshold : 60 Degree Celsius POWER is OK RPS is NOT PRESENT SWITCH: 2 FAN .

2/22/2014  · Symptom: Customer sees FAN PS- 1 is NOT PRESENT message when show env all command is entered ***** Switch#sh env all FAN is OK FAN PS- 1 is NOT PRESENT TEMPERATURE is OK Temperature Value: 33 Degree Celsius Temperature State: GREEN Yellow Threshold : 49 Degree Celsius Red Threshold : 59 Degree Celsius …

FAN 1 is OK. FAN 2 is OK. FAN PS- 1 is FAULTY . FAN PS-2 is FAULTY . SYSTEM TEMPERATURE is OK. System Temperature Value: 27 Degree Celsius. System Temperature State: GREEN. Yellow Threshold : 46 Degree Celsius. Red Threshold : 60 Degree Celsius. SW PID Serial# Status Sys Pwr PoE Pwr Watts. 1A C3KX-PWR-715WAC XXXXXXXXXXX OK Good Good 715/0 …

Out of 4 one of the switch is showing fan faulty and temperature faulty . I checked the switch and found out that the speed of the fan of that switch is higher than the speed of the fan of the other switches. How can i trouble shoot this or fix this? … FAN 1 is OK FAN 2 is OK FAN PS- 1 is OK FAN PS-2 is OK SYSTEM TEMPERATURE is OK System …

5/16/2018  · Symptom: 3560 switch’s Device Manager shows Fan FAULTY on the Dashbord as follows; FAN1 is OK FAN2 is OK FAN3 is OK FAN4 is FAULTY Conditions: FAN PS is not put in the chassis #sh env all FAN 1 is OK FAN 2 is OK FAN PS- 1 is OK FAN PS-2 is NOT PRESENT, (PS 1 Fan Fault ) Sensor [SensorElementName] has transitioned to critical from a less severe state. (PS 1 Fan Fault ) This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe. May also be shown as 800702040a01ffff or 0x800702040a01ffff …

10/28/2015  · Below is the output of show env fan and show env all. Fan1 and FAN 2 is reported ok but it shows FAN PS-2 is not present alarms me, though it looks like this is referring to redundant power supply and its fan . If it is true, why PRTG sensor is showing alarm on fan status? _SW#sh env fan FAN 1 is OK FAN 2 is OK FAN PS- 1 is OK FAN PS-2 is NOT PRESENT, 1/14/2016  · Hello, i get a wrong status for some cisco devices with the PS1 Faulty , nwc say that is critical, but at the IOS cli all locks fine. [x]# ./check_nwc_health –mode hardware-health –hostname 10.x.8 –community XX CRITICAL – powersupply…